EXIN is one of the most powerful and rapidly growing fields nowadays. Everyone is trying to get the EXIN CDCS certification to improve their futures with it. Success in the test plays an important role in the up gradation of your CV and getting a good job or working online to achieve your dreams. The students are making up their minds for the EXIN CDCS test but they are mostly confused about where to prepare for it successfully on the first try.

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.
Topic 2
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.
Topic 3
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.

>> EXIN CDCS Minimum Pass Score <<

Latest CDCS Mock Exam & CDCS Latest Exam Online

We are living in a good society; everything is changing so fast with the development of technology. So an ambitious person must be able to realize his dreams if he is willing to make efforts. Winners always know the harder they work the luckier they are. If you purchase our study materials to prepare the CDCS exam, your passing rate will be much higher than others. Also, the operation of our study material is smooth and flexible and the system is stable and powerful. You can install the CDCS Exam Guide on your computers, mobile phone and other electronic devices. There are no restrictions to the number equipment you install. In short, it depends on your own choice. We sincerely hope that you can enjoy the good service of our products.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q34-Q39):

NEW QUESTION # 34
What should you consider when using raised floor tiles with air deflectors or louvers?

  • A. Tiles with air deflectors or louvers do not allow for a flexible cooling solution.
  • B. Tiles with air deflectors or louvers will reduce the cooling capacity of the tile.
  • C. Tiles with air deflectors or louvers can be very heavy.
  • D. Tiles with air deflectors or louvers can only be used to cool storage equipment.

Answer: C

Explanation:
Raised floor tiles with air deflectors or louvers are typically heavier than standard tiles due to the additional materials and mechanisms used to direct airflow. The added weight can pose challenges for installation and adjustment, and consideration must be given to the floor's load capacity and ease of maintenance.
Detailed Explanation:
Tiles with deflectors or louvers help direct airflow, enhancing cooling efficiency by focusing cool air where needed. However, these tiles are often heavier, which can affect handling and require reinforced raised floor systems. It's essential to factor in the weight for any floor tile replacements or installations to ensure they are compatible with the raised floor's structural capacity.
EPI Data Center Specialist References:
EPI data center design training mentions the potential impact of heavy tiles on floor handling and load capacity. Data center operators need to plan for safe handling and load-bearing capacity when using such specialized tiles.


NEW QUESTION # 35
The pipes of a VESDA smoke detection system are installed at the air intake of the air conditioner inside the computer room.
Is this a good practice from an early smoke detection point of view?

  • A. No, the piping should be installed at the air exhaust of the air conditioner, as there can also be a fire inside the air conditioner itself.
  • B. It depends on the type of gas-based fire suppression which will be installed.
  • C. Yes, as this reduces the amount of piping to be installed in the data center, as all air will go through the air conditioner.
  • D. No, it will give a longer reaction time for the smoke detection system and there might also be bypass airflow.

Answer: D

Explanation:
For optimal early smoke detection in a data center, it is crucial that the Very Early Smoke Detection Apparatus (VESDA) system be installed at locations where smoke will be detected as soon as it appears. Positioning the VESDA pipes at the air intake of the air conditioner inside the computer room is not ideal. This placement could result in a delayed detection response and the potential for bypass airflow to occur, which would impede the system's ability to detect smoke effectively.
Detailed Explanation:
When VESDA pipes are installed at the air intake, the detection system relies on the smoke to be drawn into the air conditioning unit before detection can occur. This setup increases the reaction time as the smoke has to travel through the intake and get processed by the air conditioner. Furthermore, bypass airflow-a phenomenon where not all the air containing smoke particles passes through the VESDA pipes-could also delay or even prevent the system from detecting smoke early.
Ideally, VESDA pipes should be positioned where smoke is likely to accumulate first, such as near the ceiling or in the return airflow path to detect smoke at the earliest possible stage. This ensures that the detection system can quickly trigger alarms, providing more time to address potential fire hazards.
EPI Data Center Specialist References:
EPI Data Center Specialist training highlights that smoke detection should prioritize early response capabilities to maximize safety. The preferred installation for VESDA pipes is generally at points where smoke would naturally accumulate, rather than relying on air conditioning intakes where airflow can vary and delay detection. In their course materials, EPI emphasizes minimizing reaction time and reducing the impact of airflow dynamics on smoke detection efficiency.


NEW QUESTION # 36
You are installing new copper cabling.
What is the advantage or disadvantage of choosing pre-terminated category 6 or 6A cabling?

  • A. Pre-terminated cabling makes ordering of the copper cables more complex, as you need to know in advance on which side the male or female connector needs to be located.
  • B. Pre-terminated cabling is already factory tested and saves installation time.
  • C. Pre-terminated cabling has a higher fire rating.
  • D. There is no advantage as most new copper cabling network designs are based on category 3 or 5E for horizontal cabling.

Answer: B

Explanation:
Choosing pre-terminated category 6 or 6A cabling provides several advantages, primarily related to time savings and reliability. Since pre-terminated cables are factory tested, they ensure consistent quality and performance, reducing the need for additional testing during installation. This makes installation faster and more efficient, which can significantly reduce labor costs and deployment times.
Detailed Explanation:
Pre-terminated cabling systems are manufactured and tested in controlled environments, which ensures they meet industry standards for performance. This factory testing process minimizes the likelihood of faults, reducing the need for troubleshooting and retesting on-site. Moreover, pre-terminated solutions can help to streamline installations because they eliminate the need for on-site terminations, which can be time-consuming and require skilled labor.
This is especially beneficial for data centers, where rapid deployment and minimizing potential points of failure are critical to maintaining uptime. However, it is important to note that pre-terminated cables require accurate planning, as lengths and connector configurations must be predetermined.
EPI Data Center Specialist References:
According to EPI Data Center Specialist guidelines, pre-terminated cabling is advantageous in data center environments due to reduced installation time and enhanced reliability from factory testing. These attributes align with best practices for efficient data center management, where maintaining performance and minimizing downtime are priorities.


NEW QUESTION # 37
Which formula is correct?

  • A. Phase-to-Neutral Voltage = Phase-to-Phase voltage /1.732
  • B. Phase-to-Neutral Voltage = (Phase-to-Phase voltage * 1.732) / Phase-to-Neutral Voltage
  • C. Phase-to-Neutral Voltage = Phase-to-Phase voltage * 1.732
  • D. Phase-to-Neutral Voltage = Phase-to-Neutral voltage * 1.732

Answer: A

Explanation:
The correct formula for calculating Phase-to-Neutral Voltage in a three-phase power system is Phase-to-Neutral Voltage = Phase-to-Phase Voltage / 1.732. This formula applies to balanced three-phase systems, where 1.732 (or √3) represents the relationship between line-to-line and line-to-neutral voltages.
Detailed Explanation:
In three-phase systems, Phase-to-Phase Voltage is higher than Phase-to-Neutral Voltage by a factor of √3. Dividing the phase-to-phase voltage by 1.732 gives the phase-to-neutral voltage, which is critical for understanding power distribution in three-phase electrical systems commonly found in data centers.
EPI Data Center Specialist References:
EPI electrical training highlights the importance of knowing these calculations for designing and maintaining balanced power systems, which are essential for stable and efficient data center operations.


NEW QUESTION # 38
A 5kW (power consumption) server keeps crashing with the message 'temperature too high'.
The intake temperature is measured at 25 °C/77 °F and a relative humidity (RH) level of 50%.
The exhaust temperature is 29 °C/84 °F and 45% RH.
The raised floor is providing an adequate amount of CFM/CMH at a reasonable velocity.
The pressure under the raised floor is approximately 25 Pa/0.1 inch H₂O.
Analyze the situation and indicate what the most likely cause is for this server to crash.

  • A. Dust inside the server causing issues with convection-based heat transfer
  • B. The raised floor pressure is too low and/or the raised floor tile % opening is not adequate
  • C. The exhaust temperature is exceeding the ASHRAE recommended values
  • D. No cause could be determined as the CFM/CMH of the air conditioning equipment is not stated

Answer: A

Explanation:
The server's repeated overheating despite adequate intake and exhaust temperatures suggests that dust buildup inside the server may be impeding heat transfer. Dust accumulation can obstruct airflow within the server, insulate components, and disrupt the convection-based cooling systems that regulate internal temperatures, leading to overheating and potential hardware failures.
Detailed Explanation:
While the intake and exhaust temperatures appear within acceptable ranges, internal dust can reduce airflow and impede cooling efficiency, causing internal components to overheat despite seemingly normal ambient conditions. Regular cleaning and maintenance are critical for preventing dust-related issues, especially in high-powered equipment like a 5kW server.
EPI Data Center Specialist References:
EPI emphasizes regular maintenance to prevent dust buildup in data center equipment. Dust can significantly impact cooling efficiency and lead to overheating, which underlines the importance of routine cleaning for optimal server performance.


NEW QUESTION # 39
......

The development of science and technology makes our life more comfortable and convenient, which also brings us more challenges. Many company requests candidates not only have work experiences, but also some professional certifications. Therefore it is necessary to get a professional EXIN certification to pave the way for a better future. The CDCS question and answers produced by our company, is helpful for our customers to pass their CDCS exams and get the CDCS certification within several days. Our CDCS exam questions are your best choice.